Induction Heating brass mandrel die
Views Send Enquiry
   Objective Water-cooled brass mandrel die, nylon LDPE catheter, “K” type thermocouple and temperature controller.
  Material materials, supplies involved in the application
  Temperature 400°F (204°C)
  Frequency 325kHz
  Equipment Power of 10kW induction heating system, remote heat station containing one 0.66 microfarad capacitor.
  Process A two turn plate concentrator coil is used to heat the die. To measure the temperature on the ID and establish the time-totemperature relationship, the thermocouple is inserted inside the brass die. RF power is applied for 3 seconds to heat the die to 400°F (204°C). The nylon tube is pushed into the die and formed into a catheter.
  Results/Benefits Induction heating provides:
  • Increased throughput and reduced cycle time
  • Consistent and repeatable results
  • Clean heating
  • Precise temperature control  
   Heating brass mandrel die
Related Content

Air Cooled clamp coil (half-open coil) for preheating gas pipeline

induction coating by air cooled clamp induction coil

Remove plastic coating from steel tubes by Induction Heating

Releasing Fixture by Induction Heating

U shape air cooled induction coil by UM-100C-HF for pipeline preheating

induction quenching with custom-design inductor

induction brazing diamond segment

induction brass soldering copper plate_2
Hot

induction brass soldering for copper bricks
induction brass soldering stator ends of wind driven generator within 2 seconds
ultra-high frequency induction brass soldering
induction brass solering_2
induction brass solering_1
induction brass soldering_2
induction brass soldering_1
induction brass soldering

Newest Comment
No Comment
Post Comment